News

18.08.2011

New Duotrol Lipid Level 3 

This new Lipid Control is intended for in-vitro use in the quality control of HDL, LDL, Cholesterol and Triglyceride methods on clinical chemistry systems. The Lipid profile is used together with other risk factors to assess a person's risk of cardiovascular diseases. For this reason we are happy to be able to offer the new Lipid inspection Duotrol Level 3 in the pathological area (for example with values of up to 440 mg/dL for Triglyceride as well as 297 mg/dL for cholesterol) for you in your clinical chemistry laboratory.

26.05.2011

EHEC infection - now new ELISA test available from BIOMED

Currently, the number of EHEC infections in Germany is increasing. For this reason we offer you the new BIOMED E. coli Verotoxin 

1+2 Ag ELISA test for the rapid and reliable direct detection of verotoxin 1 and 2 (Shiga toxin 1 and 2) in stool samples and stool supernatants.

26.04.2011

New Clostridium difficile rapid test (toxin A/B + GDH)

With the new immunochromatographic rapid test, the simultaneous proof of toxin A/B specific, the C. difficile as well as the antigen Glutamate dehydrogenase (GDH) is possible.

The C. difficile-associated disease is the most commonly identified cause of nosocomial diarrhea with an increasing mortality rate, severity and frequency of C. difficile infection. For clinically severe cases of the disease and for all infections with ribotypes 027 and 078, a reporting requirement (accordingly to § 6 paragraph 1 no IfSG 5a) is introduced.

With this reliable test procedure from a sample receipt, a fast and accurate screening test is available on the same day.

Information on this product can be found here.

20.04.2011

New BIOMED Rota-Adeno-Kombi-Kit

BIOMED Rota-Adeno-Kombi-Kit is a rapid chromatographic immunoassay for the simultaneous qualitative detection of rotaviruses and adenoviruses in stool samples. Rotavirus and adenovirus are major causes of gastroenteritis in infants and young children but also adults. They are transmitted by fecal-oral contact and can lead to watery diarrhea and vomiting.

This new BIOMED Rota-Adeno-Kombi-Kit Benefits:

• High performance

(Sensitivity of rotavirus:> 99%, adenovirus:> 90%; Specificity of rotavirus: 98%, adenovirus:> 99%)

• simple, fast and easy handling

(In 10 minutes you have your test results)

• ready to use test kit

(Includes all components required for the test)

You can thus use the reliable BIOMED Rota-Adeno-Kombi-Kit for the fastest possible diagnosis of diarrhea. It is especially suitable for small and medium sample throughput.

17.01.2011

Latex Cystatin C reagent - a highly sensitive biomarker of renal failure

With our new cystatin C reagent you have a high quality marker to assess renal function - More sensitive than the creatinin related MDRD formula to detect the reduction of the glomerular filtration rate (eGFR).

A reduction in GFR below 60 ml/min for more than three months is a sign of chronic kidney disease. At a GFR of 60 it is also the subject of a kidney disease if albuminuria is found or there are signs of kidney damage by imaging or renal biopsy. Patients with impaired renal function have a significantly increased risk for cardiovascular morbidity and mortality.

Our turbidmetric latex test is an easy-to-use cystatin C test that can be performed with all clinical chemical analyzers. A direct comparison with known concentrations of standardized materials allows a precise determination of the value of cystatin C in serum samples.

Obviously you also receive the appropriate cystatin C controls and calibrators in the proven Biomed manner.

Interested? Contact us to request samples for testing. Product-Nr.: 122 030 for Hitachi 911, 123 030 for Hitachi 917, 133 030 for Beckman Coulter AU, 143 030 for Siemens Advia.

19.10.2010

Glucose/Lactate control new in our product portfolio

Duotrol® GluLac is an accuracy control serum of human origin with instrument specific values in the normal and pathologic range. Do not hesitate to order a free sample and test our control with your analyzer. Product-Nr. 102 671 for level 1 / 102 672 for level 2, expiration date: 04/2012.

15.10.2010

New Duocal Multi®

Our new multicalibrator for the clinical chemistry is available. You can use Duocal Multi® with the analyzer series of Roche Hitachi, Cobas, Integra, Olympus AU and Siemens Advia. The specified values are available in our download area. Product-Nr. 105 300, expiration date 08/2012.