cTnI Rapid Test – Quantitative Cardiac Troponin I

EAN: 06974464591487
Article number
5184C4X025
Packaging unit
25 test cassettes, 25 pipette tips, 1 ID chip, sample dilution buffer

Quantitative cTnI rapid test for measuring cardiac troponin I in serum, plasma and whole blood using the BIOspeed analyzer.

€162.50
Excl. 19% VAT , excl. Shipping Cost

cTnI Rapid Test Kit for Quantitative Troponin I Measurement

The cTnI Rapid Test Kit enables quantitative measurement of cardiac troponin I (cTnI) in serum, plasma and whole blood. cTnI is an important cardiac marker and can be used as a diagnostic aid in the assessment of myocardial infarction.

For quantitative cTnI measurement, the rapid test kit can be used with BIOspeed Single or BIOspeed Multi. After an incubation time of 15 minutes, the test cassette is evaluated using the BIOspeed analyzer.

What Is the Significance of Cardiac Troponin I?

Cardiac troponin I is a protein associated with cardiac muscle and is one of the established cardiac markers. Damage to myocardial tissue can result in the release of cTnI into the bloodstream. Quantitative measurement makes it possible to determine the concentration of cardiac troponin I as a numerical value.

Particularly when myocardial infarction is suspected, cTnI measurement can provide important diagnostic information. The result is not interpreted in isolation but in conjunction with other cardiac markers and the available clinical and laboratory findings.

cTnI in the Assessment of Myocardial Infarction

Quantitative cTnI measurement supports the diagnostic assessment of suspected myocardial infarction. Changes in cTnI concentration can occur in association with myocardial injury and therefore provide an important laboratory finding.

Following myocardial injury, the cTnI concentration in the blood can increase after a delay and remain elevated for several days. In addition to the measured concentration, the timing in relation to the clinical event is therefore relevant when assessing the result.

A single cTnI result is not used in isolation to establish a diagnosis. Interpretation takes into account the patient's clinical situation, other cardiac markers and the available laboratory findings.

Benefits of the cTnI Rapid Test Kit

  • Quantitative measurement of cardiac troponin I (cTnI)
  • Results after 15 minutes
  • Suitable for serum, plasma and whole blood
  • Timely cTnI measurement directly at the point of care
  • Evaluation with the BIOspeed analyzer
  • Compatible with BIOspeed Single and BIOspeed Multi
  • Test- and lot-specific information provided via the included ID chip

Quantitative cTnI Measurement Using Fluorescence Immunoassay

The cTnI Rapid Test Kit uses a fluorescence immunochromatographic assay for quantitative measurement of cardiac troponin I. Specific antibodies enable the detection of cTnI and generate a measurable fluorescence signal that is used to determine the cTnI concentration.

After incubation, the test cassette is evaluated using the BIOspeed analyzer. The lot-specific calibration curve is stored on the corresponding ID chip. Based on the measured test signal and the stored calibration data, the analyzer determines the quantitative cTnI concentration.

Performance Characteristics of the cTnI Rapid Test Kit

Parameter: Cardiac troponin I (cTnI)

Determination: Quantitative

Sample material: Serum, plasma or whole blood

Sample volume: 75 µL

Test principle: Fluorescence immunochromatographic assay

Evaluation: BIOspeed Single or BIOspeed Multi

Incubation time: 15 minutes

Kit contents: 25 test cassettes, sample dilution buffer, 25 pipette tips and 1 ID chip

cTnI in the Context of Other Cardiac Markers

Within the BIOspeed test portfolio, cardiac troponin I belongs to the group of cardiac markers. Depending on the diagnostic question, additional laboratory parameters may provide complementary information for the assessment of the cardiac situation.

In addition to cTnI, quantitative rapid tests for CK-MB, myoglobin, NT-proBNP and D-dimer are available for the BIOspeed analyzer system. These parameters provide different diagnostic information and can be selected according to the respective clinical question.

This allows different quantitative tests in the field of cardiac diagnostics to be performed using the same BIOspeed analyzer system.

cTnI Rapid Test for Point-of-Care Cardiac Diagnostics

The cTnI Rapid Test Kit enables quantitative measurement of an important cardiac marker using the BIOspeed analyzer system. Serum, plasma and whole blood can be used as sample materials, supporting integration into different diagnostic workflows.

With an incubation time of 15 minutes, the quantitative result is available promptly. The cTnI Rapid Test is therefore suitable for healthcare facilities requiring quantitative cardiac troponin I measurement directly at the point of care.

For further quantitative rapid tests and compatible analyzers, visit our BIOspeed Analyzers and Rapid Test Kits category.

More Information
Parameter cTnI (Troponin I)
Packaging unit 25 test cassettes, 25 pipette tips, 1 ID chip, sample dilution buffer
are usually dispatched on the same day (no dispatch on Fridays)
Orders placed before 12 noon
are usually dispatched on the same day (no dispatch on Fridays)
in an environmentally friendly box
Refrigerated shipping
in an environmentally friendly box
from 2.000 € Germany-wide
Free shipping
from 2.000 € Germany-wide