Only medical facilities

Myoglobin Rapid Test – Quantitative Measurement

EAN: 06974464591494
Article number
5174C4X025
Packaging unit
25 test cassettes, 25 pipette tips, 1 ID chip, sample dilution buffer

Quantitative myoglobin rapid test for measurement in serum, plasma and whole blood using the BIOspeed analyzer.

€122.50
Excl. 19% VAT , excl. Shipping Cost

Myoglobin Rapid Test Kit for Quantitative Measurement

The Myoglobin Rapid Test Kit enables quantitative measurement of myoglobin (Myo) in serum, plasma and whole blood. Myoglobin measurement can be used as a diagnostic aid in the assessment of acute myocardial infarction.

For quantitative myoglobin measurement, the rapid test kit can be used with BIOspeed Single or BIOspeed Multi. After an incubation time of 15 minutes, the test cassette is evaluated using the BIOspeed analyzer.

What Is Myoglobin?

Myoglobin is a protein found in muscle cells, where it is involved in the storage and supply of oxygen. When muscle tissue is damaged, myoglobin can be released from the affected cells into the bloodstream.

Quantitative measurement of myoglobin can therefore provide diagnostic information about possible muscle tissue damage. In cardiac diagnostics, myoglobin is used as a marker in the assessment of acute myocardial infarction.

An important consideration is that myoglobin is not found exclusively in cardiac muscle. Results are therefore interpreted together with other cardiac markers and the available clinical and laboratory findings.

What Is the Significance of Myoglobin in Acute Myocardial Infarction?

Damage to myocardial tissue can cause myoglobin to be released into the bloodstream, resulting in an increase in its concentration. Quantitative myoglobin measurement can therefore provide additional information when assessing suspected acute myocardial infarction.

One characteristic of myoglobin is its relatively early release following muscle tissue damage. This makes the timing of myoglobin measurement particularly relevant in the assessment of acute cardiac events.

However, an elevated myoglobin concentration alone is not sufficient to diagnose myocardial infarction. Other cardiac markers as well as clinical and laboratory findings are considered when interpreting the result.

Why Can Myoglobin Be Relevant as an Early Marker?

Myoglobin can be released into the bloodstream relatively early following muscle tissue damage. In acute myocardial infarction, its concentration can rise early and subsequently decrease again comparatively quickly.

When interpreting a quantitative myoglobin result, the measured concentration is therefore considered in relation to the timing of sample collection and the clinical presentation.

This characteristic can make myoglobin a useful additional parameter in cardiac diagnostics when assessed together with other cardiac markers.

Why Is Myoglobin Not Specific to the Heart?

Myoglobin is present not only in cardiac muscle but also in skeletal muscle. An elevated myoglobin concentration can therefore have different causes and is not specific to myocardial injury.

Elevated myoglobin levels may also occur, for example, following skeletal muscle injury, intense physical activity or progressive muscle atrophy.

This lack of cardiac specificity needs to be considered when interpreting the result. Myoglobin concentrations are therefore assessed in the context of the patient's clinical presentation, other cardiac markers and additional laboratory findings.

This characteristic is particularly important when considering the role of myoglobin within cardiac diagnostics.

Benefits of the Myoglobin Rapid Test Kit

  • Quantitative measurement of myoglobin
  • Results after 15 minutes
  • Suitable for serum, plasma and whole blood
  • Timely myoglobin measurement directly at the point of care
  • Evaluation with the BIOspeed analyzer
  • Compatible with BIOspeed Single and BIOspeed Multi
  • Test- and lot-specific information provided via the included ID chip

Quantitative Myoglobin Measurement Using Fluorescence Immunoassay

The Myoglobin Rapid Test Kit uses a fluorescence immunochromatographic assay for quantitative measurement of myoglobin. Specific antibodies bind to myoglobin present in the sample, generating a measurable fluorescence signal whose intensity correlates with the myoglobin concentration.

After incubation, the test cassette is evaluated using the BIOspeed analyzer. The lot-specific calibration curve is stored on the corresponding ID chip. Based on the measured test signal and the stored calibration data, the analyzer determines the quantitative myoglobin concentration.

Performance Characteristics of the Myoglobin Rapid Test Kit

Parameter: Myoglobin (Myo)

Determination: Quantitative

Sample material: Serum, plasma or whole blood

Sample volume: 75 µL

Test principle: Fluorescence immunochromatographic assay

Evaluation: BIOspeed Single or BIOspeed Multi

Incubation time: 15 minutes

Kit contents: 25 test cassettes, sample dilution buffer, 25 pipette tips and 1 ID chip

Myoglobin in the Context of Other Cardiac Markers

Within the BIOspeed test portfolio, myoglobin belongs to the group of cardiac markers. In cardiac diagnostics, myoglobin is often considered together with other laboratory parameters, as individual markers differ in their diagnostic significance and time course.

In addition to myoglobin, quantitative rapid tests for cTnI, CK-MB, NT-proBNP and D-dimer are available for the BIOspeed analyzer system. Depending on the clinical question, these parameters can be measured individually or as complementary markers and assessed together with the available clinical and laboratory findings.

For myoglobin in particular, consideration of additional cardiac markers is important because an elevated myoglobin concentration is not specific to myocardial injury.

This allows different quantitative tests in the field of cardiac diagnostics to be performed using the same BIOspeed analyzer system.

Myoglobin Rapid Test for Point-of-Care Cardiac Diagnostics

The Myoglobin Rapid Test Kit enables quantitative measurement of myoglobin using the BIOspeed analyzer system. Serum, plasma and whole blood can be used as sample materials, supporting integration into different diagnostic workflows.

With an incubation time of 15 minutes, the quantitative result is available promptly. The Myoglobin Rapid Test is therefore suitable for healthcare facilities requiring quantitative myoglobin measurement directly at the point of care and interpretation alongside other diagnostic findings.

For further quantitative rapid tests and compatible analyzers, visit our BIOspeed Analyzers and Rapid Test Kits category.

More Information
Parameter Myoglobin
Packaging unit 25 test cassettes, 25 pipette tips, 1 ID chip, sample dilution buffer
are usually dispatched on the same day (no dispatch on Fridays)
Orders placed before 12 noon
are usually dispatched on the same day (no dispatch on Fridays)
in an environmentally friendly box
Refrigerated shipping
in an environmentally friendly box
from 2.000 € Germany-wide
Free shipping
from 2.000 € Germany-wide