Only medical facilities

Duotrol® Abnormal – Quality Control for Higher Concentrations

EAN: 04260481081875
Article number
107402
Packaging unit
1 x 5 mL Lyophilisat

Lyophilized quality control serum for monitoring clinical chemistry assays at the higher control level.

 

€12.84
Excl. 19% VAT , excl. Shipping Cost

Duotrol® Abnormal – Quality Control for Higher Concentration Ranges

Duotrol® Abnormal is a lyophilized quality control serum designed to assess the precision and trueness of quantitative clinical chemistry measurements at a higher control level. It helps medical laboratories monitor analytical performance across concentration ranges that may be particularly relevant when evaluating elevated patient results.

Reliable clinical chemistry testing requires more than consistent measurements at a single concentration. Analytical variation may differ across an assay's measuring range, making an additional control level valuable for routine internal quality control.

Based on defibrinated human plasma, Duotrol® Abnormal is suitable for use with clinical chemistry analyzers when appropriate method- and instrument-specific assigned values are available. As a manufacturer-independent control material, it can be incorporated into established laboratory quality control procedures.

Why Is Quality Control at Higher Concentrations Important?

Many clinical chemistry assays are used to investigate conditions associated with increased enzyme activities, altered metabolite concentrations or changes in electrolyte levels.

For these measurements, analytical performance at higher concentrations can be just as important as performance at lower concentrations.

An assay may produce consistent results at one control level while showing increased variation or systematic deviation at another. Such differences may become apparent following recalibration, reagent lot changes, instrument maintenance or gradual changes in analytical performance.

Using Duotrol® Abnormal as an additional control level helps laboratories assess whether their methods continue to perform within established limits at higher analyte concentrations.

The name “Abnormal” identifies the control product and its higher control level. It does not mean that every analyte concentration is necessarily outside the corresponding physiological reference interval.

Assessing Concentration-Dependent Analytical Variation

Internal quality control involves measuring materials with assigned target values and comparing the results with defined control limits.

Duotrol® Abnormal supports the monitoring of analytical performance at an additional concentration level, allowing laboratories to investigate potential differences between lower and higher measurement ranges.

This is particularly useful when assessing:

  • Systematic shifts following calibration or reagent lot changes
  • Changes in measurement precision over time
  • Unexpected results at higher analyte concentrations
  • Trends that may indicate deteriorating assay performance
  • Differences in analytical behaviour between control levels

A control result outside the established limits should be investigated according to the laboratory's quality management procedures.

Duotrol® Abnormal supports ongoing analytical monitoring but does not replace instrument calibration, method verification or other required quality assurance procedures.

Clinical Chemistry Analytes Covered by Duotrol® Abnormal

Duotrol® Abnormal provides assigned values for a broad selection of quantitative clinical chemistry parameters. The available analytes and concentrations depend on the measurement method and analyzer.

Liver Enzymes and Bilirubin Measurements

Accurate measurements of liver enzymes and bilirubin are important in the assessment of hepatocellular injury, cholestasis and other hepatobiliary conditions.

Depending on the analytical method, Duotrol® Abnormal includes control values for:

  • Alanine aminotransferase (ALT)
  • Aspartate aminotransferase (AST)
  • Gamma-glutamyl transferase (GGT)
  • Alkaline phosphatase (ALP)
  • Lactate dehydrogenase (LDH)
  • Glutamate dehydrogenase (GLDH)
  • Total and direct bilirubin

For several of these analytes, the higher control level provides an opportunity to monitor assay performance at concentrations above those represented by Duotrol® Normal.

Regular control measurements help laboratories identify unexpected changes in enzyme activity or bilirubin assay performance before releasing affected patient results.

Renal Function Markers and Electrolytes

Measurements of creatinine, urea and electrolytes are frequently used to assess renal function, fluid balance and metabolic disturbances.

Duotrol® Abnormal supports quality control for suitable methods measuring creatinine, urea, uric acid, sodium, potassium, chloride, calcium, magnesium and other related parameters.

For analytes such as creatinine and potassium, the higher control level provides additional information about analytical performance at increased concentrations.

However, concentration differences between Duotrol® Normal and Duotrol® Abnormal vary by analyte. Not every parameter has a higher assigned value in Duotrol® Abnormal.

Glucose and Metabolic Testing

Glucose measurements are essential in the diagnosis and monitoring of disorders of carbohydrate metabolism.

Duotrol® Abnormal provides an additional control level for monitoring glucose assay performance at higher concentrations.

Depending on the analytical system, assigned values are also available for lipid parameters such as total cholesterol, HDL cholesterol, LDL cholesterol and triglycerides.

Monitoring these assays across more than one concentration level supports a more comprehensive assessment of analytical consistency.

Inflammatory Markers, Proteins and Other Parameters

Certain proteins and inflammatory markers are measured across broad concentration ranges in routine laboratory medicine.

Depending on the method and instrument, Duotrol® Abnormal includes assigned values for C-reactive protein (CRP), ferritin, albumin, total protein and additional clinical chemistry analytes.

Laboratories must use the assigned values and control limits applicable to their specific methods and analyzer systems.

Independent Quality Control for Clinical Chemistry Analyzers

Duotrol® Abnormal is a manufacturer-independent control serum intended for quantitative clinical chemistry testing.

Method- and instrument-specific assigned values are available for selected assays on Beckman Coulter AU and Roche cobas systems, as well as selected measurements on Siemens Atellica analyzers.

Independent control materials allow laboratories to evaluate analytical performance without relying exclusively on quality control materials supplied by the instrument or reagent manufacturer.

This can provide an additional perspective when investigating analytical shifts associated with reagent replacement, calibration changes or other modifications to the testing process.

For further information, read our article on independent quality control, Rili-BÄK, IVDR and ISO 15189.

Where assigned values are not available for a particular method, the laboratory must establish and verify suitable control ranges before routine use.

Preparing Duotrol® Abnormal for Laboratory Use

Duotrol® Abnormal is supplied as a lyophilized serum control based on defibrinated human plasma. The formulation also contains chemicals, preservatives and stabilizers.

Each vial must be reconstituted with exactly 5 mL of distilled or deionized water.

After adding the water, close the vial and allow it to stand for 30 minutes, protected from light. Gently swirl the vial occasionally to facilitate complete dissolution. Avoid foaming.

Once reconstituted, the control material is analyzed using the appropriate clinical chemistry procedure.

The measured results are compared with the applicable assigned values and control limits.

Monitoring Precision and Trueness in in vitro Diagnostic Testing

Duotrol® Abnormal is intended for internal quality control of quantitative diagnostic measurements performed in vitro.

Precision monitoring helps laboratories assess the variability of repeated measurements, while trueness assessment evaluates agreement with the assigned target value.

Lot-, method- and instrument-specific assigned values are available for the relevant analytes.

The stated control ranges are based on the maximum permissible deviations defined under the German Medical Association's laboratory quality assurance guideline (Rili-BÄK).

Laboratories should also establish their own statistical control limits and evaluate quality control results in accordance with their quality management procedures.

Two Control Levels for Broader Analytical Monitoring

Using control materials at different concentration levels helps laboratories assess analytical performance beyond a single measurement point.

Duotrol® Abnormal complements Duotrol® Normal, which represents the lower control level.

Duotrol® Normal supports routine monitoring at lower control concentrations, while Duotrol® Abnormal provides an additional level with higher assigned concentrations for many analytes.

Together, the two control sera support the identification of concentration-dependent analytical changes and enable laboratories to monitor quantitative clinical chemistry assays across different concentration ranges.

Storage and Stability After Reconstitution

Unopened vials should be stored at +2 °C to +8 °C until the stated expiry date.

For most analytes, the following stability periods apply after reconstitution when the material is protected from light:

  • +15 °C to +25 °C: 12 hours
  • +2 °C to +8 °C: 5 days
  • −15 °C to −25 °C: 28 days

Reconstituted material must not be frozen more than once.

Shorter stability periods apply to certain analytes:

  • Total bilirubin and acid phosphatase: 14 days at −15 °C to −25 °C, 1 day at +2 °C to +8 °C and 8 hours at +15 °C to +25 °C.
  • Direct bilirubin: 10 days at −15 °C to −25 °C, 1 day at +2 °C to +8 °C and 8 hours at +15 °C to +25 °C.
  • ALT: 14 days at −15 °C to −25 °C, 5 days at +2 °C to +8 °C and 12 hours at +15 °C to +25 °C.

The relevant analyte-specific stability limits must be observed when planning and performing quality control measurements.

Duotrol® Abnormal – Product Specifications

Product type: Lyophilized quality control serum

Application: Internal quality control in clinical chemistry

Control level: Higher control level

Material: Defibrinated human plasma-based control

Measurement type: Quantitative clinical chemistry assays

Compatibility: Suitable clinical chemistry analyzers with applicable assigned values

Reconstitution: 5 mL distilled or deionized water

Pack size: 1 × 5 mL

Unopened storage: +2 °C to +8 °C

Reliable Quality Control at Higher Analyte Concentrations

Duotrol® Abnormal supports medical laboratories in monitoring quantitative clinical chemistry assays at a higher control level.

Its broad analyte coverage and method-specific assigned values enable regular assessment of analytical precision and trueness across a range of clinical chemistry measurements.

Used alongside Duotrol® Normal, it provides an additional control point for evaluating analytical performance and identifying potential concentration-dependent changes.

Frequently Asked Questions About Duotrol® Abnormal

What is Duotrol® Abnormal used for?

Duotrol® Abnormal is a lyophilized quality control serum used to monitor quantitative clinical chemistry assays at the higher of two complementary control levels.

Why is a higher control level necessary?

Analytical performance may vary across an assay's measuring range. A higher control level helps laboratories assess measurement quality at an additional concentration and identify potential concentration-dependent deviations.

Which analytes can be monitored with Duotrol® Abnormal?

Depending on the analytical method, the control serum provides assigned values for liver enzymes, bilirubin, creatinine, glucose, electrolytes, lipid parameters, CRP and other clinical chemistry analytes.

Can Duotrol® Abnormal be used with different analyzer brands?

Yes. It is a manufacturer-independent control material. Laboratories must use the assigned values and control ranges applicable to their analytical methods and instruments.

Are all analyte concentrations elevated in Duotrol® Abnormal?

No. The product name identifies the higher control level, but individual analyte concentrations vary. Some parameters may not have higher assigned values than those in Duotrol® Normal.

How is Duotrol® Abnormal reconstituted?

Add exactly 5 mL of distilled or deionized water to the vial. Close it and allow it to stand for 30 minutes, protected from light. Swirl gently occasionally and avoid foaming.

How long is Duotrol® Abnormal stable after reconstitution?

For most analytes, the control is stable for five days at +2 °C to +8 °C or 28 days at −15 °C to −25 °C, provided that it is frozen only once. Shorter stability periods apply to selected analytes.

More Information
Parameter Albumin, ALT / GPT, ALP / AP, Amylase, ASL-O, Bilirubin, Bilirubin Direct, Bilirubin Total, Calcium, Chlorid, Cholesterol, CHE, CK-NAC, CK-MB, Creatinine, CRP, Iron, Ferritin, Total Protein, gGT, Glucose, GLDH, Uric Acid, Urea, HBDH, HDL-Cholesterol, IgA, IgG, IgM, Potassium, Lactate, LDH, LDL-Cholesterin, Lipase, Lithium, Magnesium, Sodium, Osmolality, Pankreas-Amylase, Phosphat, Acid Phosphatase, Transferrin, Triglyceride
Packaging unit 1 x 5 mL Lyophilisat

If required, we can provide you with device-specific target values using statistical analysis. Information on participating in target value determination can be found here.

A product-specific IFU, including current target values, safety data sheets (MSDS), data sheets instead of MSDS, and CoAs are available as PDF downloads directly from our database: https://dokumente.biomed.de/

You will find your login details on your delivery note.

are usually dispatched on the same day (no dispatch on Fridays)
Orders placed before 12 noon
are usually dispatched on the same day (no dispatch on Fridays)
in an environmentally friendly box
Refrigerated shipping
in an environmentally friendly box
from 2.000 € Germany-wide
Free shipping
from 2.000 € Germany-wide