Only medical facilities

Duotrol® Elpho Kapillar Level 1 – Serumeiweiß-Elektrophorese

EAN: 04260481080540
Article number
107105
Packaging unit
2 x 2 mL

Lyophilized control serum for quality control of serum protein electrophoresis by capillary electrophoresis.

€145.19
Excl. 19% VAT , excl. Shipping Cost

Duotrol® Elpho Capillary Level 1 – Quality Control for Serum Protein Electrophoresis

Duotrol® Elpho Capillary Level 1 is a lyophilized quality control serum designed for serum protein electrophoresis using capillary electrophoresis systems. It enables medical laboratories to monitor the precision and accuracy of quantitative serum protein fractionation as part of routine internal quality control.

Level 1 represents one of two clinically relevant control levels available for Duotrol® Elpho Capillary. It provides a defined protein distribution for monitoring the separation and quantification of albumin and the α1, α2, β1, β2 and γ globulin fractions.

Duotrol® Elpho Capillary Level 2 provides a complementary control with a different protein fraction pattern, allowing laboratories to assess analytical performance using two distinct control profiles.

Quality Control in Serum Protein Electrophoresis

Serum protein electrophoresis separates serum proteins into characteristic fractions according to their electrophoretic properties. Accurate separation and quantification of these fractions are essential for obtaining reliable analytical results.

Quality control in capillary electrophoresis therefore involves more than monitoring a single concentration. The analytical system must consistently distinguish and quantify the individual protein fractions and reproduce the expected distribution pattern.

Duotrol® Elpho Capillary Level 1 provides a defined control profile for this purpose. It is used alongside human serum samples within the laboratory's established quality control procedures and is intended exclusively for diagnostic measurements in vitro using capillary electrophoresis systems.

Which Protein Fractions Are Monitored with Level 1?

Device- and method-specific target values and target ranges are available for the major fractions assessed by serum protein electrophoresis:

  • Albumin
  • α1 globulin
  • α2 globulin
  • β1 globulin
  • β2 globulin
  • γ globulin

A target range is also available for total protein determined by the biuret method.

This multiparameter approach allows laboratories to monitor both individual fractions and the overall analytical performance of serum protein separation.

Monitoring Protein Fractionation with a Defined Control Profile

Duotrol® Elpho Capillary Level 1 is designed to provide a defined electrophoretic protein distribution for routine quality control.

This is particularly relevant in serum protein electrophoresis because analytical variation can affect the measured proportions of individual fractions and consequently alter the resulting electrophoretic profile.

Regular control measurements help laboratories identify analytical shifts and monitor whether the capillary electrophoresis system continues to separate and quantify serum protein fractions consistently.

Rather than focusing solely on total protein concentration, Level 1 enables the analytical process of protein fractionation itself to be monitored.

Target Values for Capillary Electrophoresis Systems

Target values for Duotrol® Elpho Capillary are established on a lot-specific basis using representative measurements. Depending on the analytical setup, values are assigned for specific systems or methods.

Target values for Level 1 are available for systems including:

  • V8 Clinical Capillary Electrophoresis System
  • Fast-CE
  • Sebia Capillaris

The assigned values and ranges vary according to the system used. Laboratories working with systems for which no assigned values are available should establish their own target ranges.

Good laboratory practice also recommends that laboratories define their own control ranges according to their analytical methods and local operating conditions.

Independent Quality Control for Capillary Electrophoresis

Duotrol® Elpho Capillary is manufactured independently of the manufacturers of the analytical systems with which it is used. It has not been developed exclusively for instruments, test kits or methods from a particular manufacturer.

Independent control material provides an additional means of assessing analytical performance without relying solely on system-specific quality control materials.

For laboratories using capillary electrophoresis, this supports independent monitoring of serum protein fractionation and integration of the results into established laboratory quality assurance procedures.

Lyophilized Human Serum Control

Duotrol® Elpho Capillary Level 1 is supplied as a lyophilized control serum based on pooled human serum with preservatives and stabilizers.

The lyophilized material must be reconstituted before analysis. Once prepared, the control is processed in the respective capillary electrophoresis system in the same manner as a patient sample.

How Is Duotrol® Elpho Capillary Level 1 Reconstituted?

The contents of one vial are carefully dissolved in exactly 2 mL of distilled or deionized water.

The vial is then gently swirled, securely closed and allowed to stand for 20 minutes. During this period, it should be gently swirled occasionally while avoiding foam formation.

Before each use, the reconstituted control should be mixed by gentle inversion to obtain a homogeneous solution.

Consistent reconstitution helps ensure that the control material is prepared under reproducible conditions before analysis.

How Is Level 1 Used in Routine Laboratory Testing?

After reconstitution, Duotrol® Elpho Capillary Level 1 is processed in the capillary electrophoresis system in the same way as a patient sample and according to the requirements of the respective analyzer.

A suitable separation medium, buffer and other consumables required by the analytical system are needed for testing.

The measured protein fractions are compared with the appropriate target values or control ranges. This enables the laboratory to determine whether electrophoretic separation and quantification remain within the established quality requirements.

Why Use Level 1 and Level 2?

Duotrol® Elpho Capillary is available in two clinically relevant control levels. The distinction between the two controls is not simply based on a uniformly lower or higher protein concentration.

Instead, Level 1 and Level 2 provide different distributions of the individual serum protein fractions.

Level 1 offers a defined protein profile for routine monitoring of serum protein fractionation. Duotrol® Elpho Capillary Level 2 complements this with a different electrophoretic pattern, including a substantially higher proportion of γ globulin.

Using both control levels therefore allows laboratories to assess analytical performance across different protein distribution patterns rather than relying on a single control profile.

Storage and Stability

Unopened Duotrol® Elpho Capillary Level 1 should be stored in its original packaging at +2 °C to +8 °C and remains stable until the stated expiry date when stored correctly.

After reconstitution and protected from light, the control material remains stable:

  • for 5 days at +2 °C to +8 °C
  • for 2 months when aliquoted and stored at −20 °C

Material stored at −20 °C must only be frozen once.

Product Characteristics

Product: Duotrol® Elpho Capillary Level 1

Application: Quality control for serum protein electrophoresis

Method: Capillary electrophoresis

Control material: Lyophilized pooled human serum

Protein fractions: Albumin, α1, α2, β1, β2 and γ globulins

Additional parameter: Total protein

Reconstitution: Exactly 2 mL distilled or deionized water per vial

Contents: 2 × 2 mL

Use: Capillary electrophoresis systems

Reliable Quality Control for Serum Protein Fractionation

Duotrol® Elpho Capillary Level 1 provides medical laboratories with an independent control serum for monitoring serum protein electrophoresis. Its defined protein fraction profile supports quantitative assessment of albumin and the major globulin fractions and helps laboratories monitor the analytical performance of capillary electrophoresis systems over time.

Lot-specific, device- or method-specific target values support integration into routine quality control procedures.

Duotrol® Elpho Capillary Level 2 is available as a complementary control with a different protein distribution profile. Additional control materials for other areas of laboratory diagnostics are available in our Quality Controls category.

Frequently Asked Questions About Duotrol® Elpho Capillary Level 1

What is Duotrol® Elpho Capillary Level 1?

Duotrol® Elpho Capillary Level 1 is a lyophilized human serum control for quality control of serum protein electrophoresis using capillary electrophoresis systems. It is designed to monitor the precision and accuracy of quantitative protein fractionation.

Which protein fractions can be monitored?

The control covers albumin and the α1, α2, β1, β2 and γ globulin fractions. A target range for total protein determined by the biuret method is also available.

Does Duotrol® Elpho Capillary Level 1 require reconstitution?

Yes. The lyophilized control must be reconstituted with exactly 2 mL of distilled or deionized water before use.

How long should the control stand after reconstitution?

After adding the water, the vial should be gently swirled, securely closed and left to stand for 20 minutes. It should be gently swirled occasionally during this period while avoiding foam formation.

Which analytical systems can be used?

Duotrol® Elpho Capillary is intended exclusively for capillary electrophoresis systems. Assigned target values are available for systems including the V8 Clinical Capillary Electrophoresis System, Fast-CE and Sebia Capillaris.

How do Level 1 and Level 2 differ?

The two levels provide different serum protein distribution patterns. Level 1 offers a defined profile for routine monitoring of protein fractionation, while Level 2 provides a complementary pattern with differences in individual fractions, including a substantially higher γ globulin proportion.

How stable is Level 1 after reconstitution?

When protected from light, the reconstituted control remains stable for 5 days at +2 °C to +8 °C. When aliquoted, it can be stored for 2 months at −20 °C and must only be frozen once.

More Information
Parameter α1-Globulin, α2-Globulin, ß1-Globulin, ß2-Globulin, Albumin, Total Protein, γ-Globulin
Packaging unit 2 x 2 mL

If required, we can provide you with device-specific target values using statistical analysis. Information on participating in target value determination can be found here.

A product-specific IFU, including current target values, safety data sheets (MSDS), data sheets instead of MSDS, and CoAs are available as PDF downloads directly from our database: https://dokumente.biomed.de/

You will find your login details on your delivery note.

are usually dispatched on the same day (no dispatch on Fridays)
Orders placed before 12 noon
are usually dispatched on the same day (no dispatch on Fridays)
in an environmentally friendly box
Refrigerated shipping
in an environmentally friendly box
from 2.000 € Germany-wide
Free shipping
from 2.000 € Germany-wide