Duotrol® Elpho Capillary Level 2 – Protein Fraction Control
Lyophilized control serum for quality control of altered serum protein fraction patterns by capillary electrophoresis.
Duotrol® Elpho Capillary Level 2 – Quality Control for Altered Protein Fraction Patterns
Duotrol® Elpho Capillary Level 2 is a lyophilized control serum for serum protein electrophoresis using capillary electrophoresis systems. It provides a distinctly different serum protein distribution compared with Level 1, allowing laboratories to assess analytical performance using an additional electrophoretic control profile.
Level 2 is characterized in particular by a higher proportion of γ globulin and changes in other protein fractions. At the same time, the albumin fraction is lower than in Level 1. This makes Level 2 a complementary control for monitoring the reliable separation and quantification of serum proteins across different fraction patterns.
Duotrol® Elpho Capillary Level 2 is intended for the quantitative assessment of precision and accuracy of diagnostic measurements in vitro and is designed exclusively for use with capillary electrophoresis systems.
Why Are Different Protein Fraction Patterns Important in Quality Control?
Serum protein electrophoresis does not assess total protein concentration alone. The analytical process must reliably separate serum proteins into their individual fractions and quantify their relative distribution.
Albumin and the α1, α2, β1, β2 and γ globulin fractions form a characteristic electrophoretic pattern. Changes in the relative proportions of these fractions result in a different protein profile.
For this reason, monitoring a capillary electrophoresis system with only one control pattern provides a limited view of analytical performance. Duotrol® Elpho Capillary Level 2 adds a second, clearly differentiated control profile and complements routine quality control with Level 1.
What Makes Duotrol® Elpho Capillary Level 2 Different?
Level 2 is not simply a higher-concentration version of Level 1. Instead, the relative distribution of several serum protein fractions is different.
The difference is particularly evident in the γ globulin fraction. Depending on the capillary electrophoresis system, Level 2 has a γ globulin target value of approximately 24%, compared with approximately 12% for Level 1.
The β2 globulin fraction is also more pronounced in Level 2, while the albumin fraction is lower. Exact target values depend on the analytical system used.
This distinct distribution makes Level 2 an independent control profile for monitoring the analytical performance of serum protein fractionation rather than merely representing a higher protein concentration.
Which Protein Fractions Can Be Monitored with Level 2?
Target values and target ranges are available for the major fractions assessed in serum protein electrophoresis:
- Albumin
- α1 globulin
- α2 globulin
- β1 globulin
- β2 globulin
- γ globulin
A target range is also available for total protein determined by the biuret method.
Monitoring these parameters together allows laboratories to assess whether the capillary electrophoresis system reliably separates and quantifies serum proteins when presented with a protein distribution that differs from the Level 1 control profile.
Monitoring an Increased γ Globulin Fraction
The γ globulin fraction is a particularly distinctive feature of Duotrol® Elpho Capillary Level 2. Compared with Level 1, its proportion is substantially higher, providing a control profile with an increased γ globulin fraction.
This is relevant to analytical quality control because a capillary electrophoresis system must be capable of reliably identifying and quantifying different distributions of serum protein fractions.
Duotrol® Elpho Capillary Level 2 is intended solely for analytical quality control. Its protein distribution is a defined control profile and should not be interpreted as a patient result or clinical diagnosis.
Target Values for Different Capillary Electrophoresis Systems
Target values for Duotrol® Elpho Capillary are established on a lot-specific basis using representative measurements. Depending on the analytical setup, the values are assigned to specific systems or methods.
Target values for Level 2 are available for systems including:
- V8 Clinical Capillary Electrophoresis System
- Fast-CE
- Sebia Capillaris
The assigned target values and ranges vary between analytical systems and should therefore be interpreted according to the method and system used by the laboratory.
Laboratories using capillary electrophoresis systems for which no assigned target values are available should establish their own target ranges. Good laboratory practice also recommends defining laboratory-specific control ranges according to the analytical method and local operating conditions.
Independent Control Serum for Serum Protein Electrophoresis
Duotrol® Elpho Capillary is manufactured independently of the manufacturers of the analytical systems with which it is used. The control material has not been developed exclusively for instruments, test kits or methods from a specific manufacturer.
Independent control material provides laboratories with an additional means of monitoring analytical performance without relying solely on system-specific quality control materials.
The use of different control profiles can further support a differentiated assessment of protein fractionation as part of internal laboratory quality assurance.
Lyophilized Human Serum Control
Duotrol® Elpho Capillary Level 2 is based on pooled human serum and is supplied in lyophilized form. The control material also contains preservatives and stabilizers.
The lyophilized material must be reconstituted before use. Once prepared, the control is processed according to the requirements of the respective capillary electrophoresis system in the same way as a patient sample.
A suitable separation medium, buffer and other consumables required by the analytical system are needed for testing.
How Is Duotrol® Elpho Capillary Level 2 Prepared?
For reconstitution, the contents of one vial are carefully dissolved in exactly 2 mL of distilled or deionized water.
The vial is then gently swirled, securely closed and allowed to stand for 20 minutes. During this period, it should be gently swirled occasionally while avoiding foam formation.
Before each use, the reconstituted control is mixed by gentle inversion to obtain a homogeneous solution.
After preparation, Level 2 can be incorporated into the laboratory's internal quality control procedures according to the requirements of the respective capillary electrophoresis system.
Level 2 as a Complement to Level 1
Duotrol® Elpho Capillary Level 1 and Level 2 provide two different clinically relevant control levels for serum protein electrophoresis.
Level 1 offers a defined protein distribution for routine monitoring of electrophoretic protein fractionation.
Level 2 extends this approach with a distinctly different fraction pattern. Its characteristic features include a higher proportion of γ globulin and β2 globulin together with a lower albumin fraction compared with Level 1.
Using both controls therefore enables laboratories to assess analytical performance with different protein distributions instead of relying on a single electrophoretic control profile.
Storage After Reconstitution
Unopened Duotrol® Elpho Capillary Level 2 should be stored in its original packaging at +2 °C to +8 °C. When stored correctly, it remains stable until the stated expiry date.
After reconstitution, the control material should be protected from light.
At +2 °C to +8 °C, the reconstituted control remains stable for 5 days.
For longer storage, the material can be aliquoted and stored at −20 °C for up to 2 months. It must only be frozen once.
Product Characteristics
Product: Duotrol® Elpho Capillary Level 2
Application: Quality control of altered serum protein fraction patterns
Method: Serum protein electrophoresis by capillary electrophoresis
Control material: Lyophilized pooled human serum
Protein fractions: Albumin, α1, α2, β1, β2 and γ globulins
Profile: Higher γ globulin and β2 globulin proportions compared with Level 1
Additional parameter: Total protein
Reconstitution: Exactly 2 mL distilled or deionized water per vial
Contents: 2 × 2 mL
Use: Capillary electrophoresis systems
Duotrol® Elpho Capillary Level 2 for Differentiated Quality Control
Duotrol® Elpho Capillary Level 2 extends quality control of serum protein electrophoresis by providing a distinct protein fraction profile. The more pronounced γ globulin and β2 globulin fractions together with the lower albumin proportion differentiate Level 2 from the distribution found in Level 1.
This enables medical laboratories to assess whether their capillary electrophoresis system continues to provide reliable separation and quantitative measurement when analyzing a different serum protein distribution.
Duotrol® Elpho Capillary Level 1 complements Level 2 with a separate control profile. Additional independent control materials for laboratory diagnostics are available in our Quality Controls category.
Frequently Asked Questions About Duotrol® Elpho Capillary Level 2
What Is Duotrol® Elpho Capillary Level 2?
Duotrol® Elpho Capillary Level 2 is a lyophilized control serum for quality control of serum protein electrophoresis using capillary electrophoresis. It provides a protein fraction pattern that differs from the Level 1 control profile.
What Is Characteristic of the Level 2 Protein Profile?
Level 2 is characterized in particular by a substantially higher γ globulin proportion compared with Level 1. The β2 globulin fraction is also more pronounced, while the albumin proportion is lower. Exact target values depend on the capillary electrophoresis system used.
Which Protein Fractions Are Monitored?
The control includes albumin and the α1, α2, β1, β2 and γ globulin fractions. A target range for total protein determined by the biuret method is also available.
Why Use Both Level 1 and Level 2?
The two controls provide different serum protein distributions. Using both profiles allows laboratories to monitor the analytical performance of a capillary electrophoresis system with different electrophoretic fraction patterns.
Which Analytical Systems Can Be Used?
Duotrol® Elpho Capillary is intended exclusively for capillary electrophoresis systems. Assigned target values are available for systems including the V8 Clinical Capillary Electrophoresis System, Fast-CE and Sebia Capillaris.
Does Level 2 Require Reconstitution?
Yes. The lyophilized control serum must be reconstituted with exactly 2 mL of distilled or deionized water. After reconstitution, the vial is allowed to stand for 20 minutes.
How Stable Is Level 2 After Reconstitution?
When protected from light, the reconstituted control remains stable for 5 days at +2 °C to +8 °C. When aliquoted, it can be stored for 2 months at −20 °C and must only be frozen once.
| Parameter | α1-Globulin, α2-Globulin, ß1-Globulin, ß2-Globulin, Albumin, Total Protein, γ-Globulin |
|---|---|
| Packaging unit | 2 x 2 ml |
If required, we can provide you with device-specific target values using statistical analysis. Information on participating in target value determination can be found here.
A product-specific IFU, including current target values, safety data sheets (MSDS), data sheets instead of MSDS, and CoAs are available as PDF downloads directly from our database: https://dokumente.biomed.de/
You will find your login details on your delivery note.