Only medical facilities

Duotrol® U Dipstick Level 1 – Urine Test Strip Control

EAN: 04260481081882
Article number
107460
Packaging unit
1 x 15 mL

Liquid urine quality control for reagent strip testing in the lower control range.

€34.33
Excl. 19% VAT , excl. Shipping Cost

Duotrol® U Dipstick Level 1 – Quality Control for Urine Test Strips

Duotrol® U Dipstick Level 1 is a liquid urine quality control for qualitative and semi-quantitative testing in urine diagnostics. It represents the lower of two clinically relevant control levels and is particularly suitable for monitoring negative or low-level results in routine urinalysis.

For many common urine test strip parameters, Level 1 provides negative or low-level control results. Depending on the test strip or analyzer used, these include protein, glucose, ketones, bilirubin, blood, nitrite and leukocytes. Additional parameters from chemical, physical and microscopic urine analysis can also be monitored.

As a ready-to-use liquid control, Duotrol® U Dipstick Level 1 does not require reconstitution. It supports medical laboratories in routinely checking the performance of urine reagent strips, visual interpretation and suitable automated reading systems.

Why Is Quality Control Important in Urine Test Strip Analysis?

Urine reagent strips are widely used in laboratories and other professional diagnostic settings to assess several biochemical parameters from a single urine sample.

Reliable testing requires more than the correct detection of positive reactions. The analytical system must also distinguish negative results from measurable or positive reactions consistently. Changes in reagent strip performance, lot-to-lot variation, storage conditions or instrumental reading can affect analytical results.

Routine internal quality control helps laboratories identify such changes and monitor the reliability of their urinalysis procedures.

Duotrol® U Dipstick Level 1 focuses on the lower control range. For many clinically relevant reagent strip parameters, the expected results are negative or within a low range, making Level 1 particularly useful for monitoring this part of the analytical process.

Monitoring Negative Urine Test Strip Reactions

A negative test result is analytically just as important as a positive one. Urine test strips and their reading systems must reliably distinguish a negative reaction from a detectable or positive result.

With Duotrol® U Dipstick Level 1, many validated reagent strip systems provide negative or low-level results for parameters including:

  • Protein
  • Glucose
  • Ketones
  • Bilirubin
  • Blood
  • Nitrite
  • Leukocytes or leukocyte esterase

Depending on the analytical system, target values or expected ranges are also available for additional parameters.

This makes Level 1 particularly suitable for routine monitoring of negative reactions and lower measurement ranges in urine test strip analysis.

More Than a Urine Test Strip Control

Duotrol® U Dipstick Level 1 is not limited to chemical reagent strip testing.

Depending on the method used, the control can also support quality control in other areas of urinalysis. These include physical measurements such as specific gravity and osmolality as well as suitable microscopic examinations.

For selected methods and systems, control values are also available for additional parameters such as creatinine, albumin or microalbumin and hCG.

This broad range of applications allows Duotrol® U Dipstick Level 1 to be incorporated into different professional urinalysis workflows.

Visual and Automated Urine Test Strip Reading

Urine reagent strips may be evaluated visually using the manufacturer's color chart or with a suitable automated strip reader.

Duotrol® U Dipstick Level 1 can support both approaches when the respective method is intended for use with the control.

For visual interpretation, the reagent strip is exposed to the control urine and evaluated according to the instructions for the respective test strip. With automated methods, the strip is measured using the corresponding analyzer.

This allows laboratories to monitor both reagent strip performance and the reliability of the reading process.

Target Values for Different Urinalysis Systems

Duotrol® U Dipstick has been evaluated with a range of urine reagent strips and analytical systems. Target values or expected ranges are available for systems from manufacturers including Roche, Siemens, Sysmex, ACON, Arkray, Macherey-Nagel and DFI.

Results can vary depending on the reagent strip, analyzer, method and reagent lot. The appropriate target values or expected ranges for the specific analytical system should therefore be used when assessing control results.

Good laboratory practice also recommends that laboratories establish their own control ranges under their individual analytical conditions.

Ready-to-Use Liquid Urine Control

Duotrol® U Dipstick Level 1 is based on a liquid human urine matrix. The control also contains purified components of human and animal origin, purified chemicals, preservatives and stabilizers.

Because the material is supplied in liquid form, no reconstitution is required.

Before use, the control vial should be mixed thoroughly by gentle inversion for approximately three minutes to obtain a homogeneous solution. The contents should then be brought to room temperature.

The control is used in the respective analytical procedure in the same way as a patient sample.

Quality Control for Diagnostic Testing in vitro

Duotrol® U Dipstick Level 1 is intended for quality control of diagnostic testing in vitro and is used alongside human urine samples within the laboratory's established quality control procedures.

Measured results can be compared with the appropriate expected ranges to assess whether reagent strips and, where applicable, analytical instruments continue to perform within the laboratory's defined quality requirements.

Duotrol® U Dipstick is manufactured independently of instrument manufacturers and is not designed exclusively for the instruments, test kits or methods of a single manufacturer. This allows laboratories to use independent control material when monitoring analytical performance in urinalysis.

Level 1 and Level 2 Monitor Different Control Ranges

Reliable quality control should assess more than one analytical response range. Duotrol® U Dipstick is therefore available in two clinically relevant control levels.

Level 1 focuses on the lower control range. For many common reagent strip parameters, negative or low-level results are expected.

Duotrol® U Dipstick Level 2 complements this profile with positive reactions and higher measurement ranges. Depending on the analytical system, parameters such as protein, glucose, ketones, bilirubin, blood and leukocytes show positive or increased control results with Level 2. Nitrite, for example, is negative in Level 1 and positive in Level 2.

Using both levels enables laboratories to monitor different response ranges of urine reagent strips and their associated reading systems.

Storage and Stability

Unopened Duotrol® U Dipstick Level 1 should be stored protected from light at +2 °C to +8 °C. When stored correctly in its original packaging, the control remains stable until the stated expiry date.

Do not freeze.

After opening and when protected from light, the parameters remain stable:

  • for 6 weeks at +18 °C to +25 °C
  • for 3 months at +2 °C to +8 °C

The vial should be closed immediately after use. Prolonged exposure to air should be avoided because evaporation may particularly affect electrolyte results.

Product Characteristics

Product: Duotrol® U Dipstick Level 1

Application: Quality control for urinalysis

Control level: Lower control range

Primary focus: Monitoring negative and low-level test reactions

Control material: Liquid control based on human urine

Testing: Qualitative and semi-quantitative urine analysis

Applications: Biochemical, chemical and microscopic urinalysis

Evaluation: Visual or with suitable analytical systems

Reconstitution: Not required

Contents: 1 × 15 mL

Storage before opening: +2 °C to +8 °C, protected from light

Duotrol® U Dipstick Level 1 for Routine Urinalysis

Duotrol® U Dipstick Level 1 provides targeted quality control for the lower measurement and response ranges encountered in urinalysis. In urine reagent strip testing, it allows laboratories to verify whether negative and low-level results are detected and interpreted reliably.

The liquid urine matrix is ready to use and can be incorporated into both manual procedures and suitable automated urine test strip and urinalysis systems.

Duotrol® U Dipstick Level 2 complements Level 1 by providing positive reactions and higher control ranges. Together, the two levels support differentiated monitoring of analytical performance across clinically relevant response ranges.

Additional independent control materials for other areas of laboratory diagnostics are available in our Quality Controls category.

Frequently Asked Questions About Duotrol® U Dipstick Level 1

What Is Duotrol® U Dipstick Level 1?

Duotrol® U Dipstick Level 1 is a liquid quality control for qualitative and semi-quantitative urinalysis. It represents the lower of the two available clinically relevant control levels.

Which Parameters Can Be Monitored with Level 1?

Depending on the reagent strip or analytical system, parameters including protein, glucose, ketones, bilirubin, blood, nitrite, urobilinogen, leukocytes, specific gravity and additional urine parameters can be monitored.

Why Are Many Parameters Negative in Level 1?

Level 1 is designed to monitor the lower control range. An analytical system must reliably identify whether a parameter is negative or remains within a low measurement range. Monitoring negative reactions is therefore an important part of analytical quality control.

Can Level 1 Be Used with Automated Urine Strip Readers?

Yes, when the respective analytical system is intended for use with the control. Depending on the method, Duotrol® U Dipstick can be evaluated visually or with suitable automated systems.

Does Duotrol® U Dipstick Level 1 Require Reconstitution?

No. The control is supplied as a liquid urine control and is ready to use without reconstitution. Before use, the vial should be gently inverted for approximately three minutes and brought to room temperature.

What Is the Difference Between U Dipstick Level 1 and Level 2?

Level 1 primarily monitors negative and low-level test reactions. Level 2 provides positive reactions and higher measurement ranges for numerous urine parameters. The two control levels therefore complement each other when monitoring urine reagent strip performance.

How Long Is an Opened Vial Stable?

When protected from light, the parameters remain stable for 3 months at +2 °C to +8 °C or for 6 weeks at +18 °C to +25 °C.

More Information
Parameter Albumin, Bilirubin, Blood (hemoglobin), Creatinine, Protein, Protein / Crea ratio, Glucose, hCG, Ketones, Leukocytes, Microalbumin, Sodium, Nitrite, Osmolality, pH, spec. weight, Urobilinogen
Packaging unit 1 x 15 mL

If required, we can provide you with device-specific target values using statistical analysis. Information on participating in target value determination can be found here.

A product-specific IFU, including current target values, safety data sheets (MSDS), data sheets instead of MSDS, and CoAs are available as PDF downloads directly from our database: https://dokumente.biomed.de/

You will find your login details on your delivery note.

are usually dispatched on the same day (no dispatch on Fridays)
Orders placed before 12 noon
are usually dispatched on the same day (no dispatch on Fridays)
in an environmentally friendly box
Refrigerated shipping
in an environmentally friendly box
from 2.000 € Germany-wide
Free shipping
from 2.000 € Germany-wide