Duotrol® U Dipstick Level 2 – Elevated Urine Parameters
Ready-to-use liquid quality control for urinalysis in the higher control range.
Duotrol® U Dipstick Level 2 – Quality Control for Elevated Urine Parameters
Duotrol® U Dipstick Level 2 is a ready-to-use liquid urine control for qualitative and semi-quantitative urinalysis. It represents the higher of two clinically relevant control levels and is designed to monitor positive reactions and elevated results across a broad range of urine parameters.
Depending on the reagent strip or analytical system used, Level 2 provides positive or elevated control ranges for parameters including protein, glucose, ketones, bilirubin, blood, nitrite, urobilinogen and leukocytes. Suitable methods also allow additional parameters such as creatinine, albumin or microalbumin and hCG to be monitored.
This makes Duotrol® U Dipstick Level 2 particularly useful for verifying whether reagent strips and compatible urinalysis systems reliably detect analytes when they are present and correctly reproduce the expected response range.
Quality Control Across Positive and Elevated Result Ranges
Reliable urinalysis requires analytical systems to perform correctly across different response ranges. It is not sufficient to verify only whether a test strip produces a negative result. Positive reactions and elevated values must also be detected consistently and assigned to the appropriate semi-quantitative range.
Duotrol® U Dipstick Level 2 is specifically suited to this part of quality control.
The control contains various parameters at concentrations that produce positive reactions with the evaluated reagent strip systems. Laboratories can therefore assess whether the relevant test fields respond as expected and whether visual or automated interpretation produces results within the specified ranges.
This is particularly important for semi-quantitative urine reagent strips, where results are often divided into several concentration or reaction levels rather than simply reported as positive or negative.
Which Urine Parameters Can Be Monitored with Level 2?
Depending on the reagent strip, method and analytical system, target values or expected ranges are available for parameters including:
- Protein
- Glucose
- Ketones
- Bilirubin
- Blood
- Nitrite
- Urobilinogen
- Leukocytes or leukocyte esterase
- Specific gravity
- Creatinine
- Albumin or microalbumin
Additional parameters can be monitored with selected systems and methods.
The assigned values are method- and system-specific. Control results should therefore always be evaluated against the appropriate ranges for the reagent strip or analytical system used by the laboratory.
Monitoring Protein and Albumin in Urine
Protein testing is an established component of routine urinalysis. Duotrol® U Dipstick Level 2 provides positive protein reactions across the evaluated reagent strip systems, with the exact response depending on the respective method.
For suitable analytical systems, assigned values are also available for albumin or microalbumin. This allows corresponding test fields or analytical methods to be included in routine quality control.
Some systems additionally provide elevated control ranges for creatinine. Where supported by the method, the protein-to-creatinine ratio can also be assessed.
Level 2 therefore supports quality control beyond conventional qualitative protein testing and can cover additional parameters used in professional urine analysis.
Positive Glucose and Ketone Reactions
Duotrol® U Dipstick Level 2 also provides positive control ranges for glucose and ketones.
The expected concentration and reaction levels vary between reagent strips and analytical systems. This allows laboratories to verify whether the respective test fields respond correctly to the presence of glucose or ketones and whether the resulting reaction falls within the expected range.
For semi-quantitative reagent strips, this is particularly relevant because the analytical result may be divided into several concentration categories. A control in the elevated range therefore helps monitor not only the occurrence of a reaction but also its correct interpretation.
Monitoring Nitrite, Blood and Leukocytes
Nitrite, blood and leukocytes are common parameters in urine reagent strip testing.
With Duotrol® U Dipstick Level 2, nitrite is expected to produce a positive result with the listed reagent strip systems. Positive ranges are also provided for blood and leukocytes or leukocyte esterase.
This enables laboratories to verify that the corresponding test fields respond to the control material and that the results are reported within the expected range.
The exact reaction level depends on the reagent strip and reading system used.
hCG and Additional Urinalysis Parameters
The scope of Duotrol® U Dipstick Level 2 extends beyond conventional urine reagent strip parameters.
For a number of listed hCG test systems, Level 2 provides a positive control result. It can therefore be used to monitor these methods where corresponding target values are available.
Physical urine parameters can also be included in quality control. These include specific gravity and osmolality.
For suitable procedures, expected ranges are additionally available for microscopic urine components. Level 2 can therefore support quality control across several areas of professional urinalysis rather than being limited to standard reagent strip testing.
Visual and Automated Evaluation
Duotrol® U Dipstick Level 2 can be used with visual or instrumental evaluation, depending on the intended analytical method.
For visual reagent strip testing, the reaction is assessed according to the instructions for the respective test strip. Automated procedures use the corresponding urine strip reader or urinalysis system.
Target values or expected ranges are available for numerous established reagent strips and analytical systems, including systems from Roche, Siemens, Sysmex, ACON, Arkray, Macherey-Nagel and other manufacturers.
Because test principles, concentration ranges and reporting categories may differ between systems, control results must always be interpreted using the values assigned to the respective method.
Ready-to-Use Liquid Urine Control
Duotrol® U Dipstick Level 2 is based on a liquid human urine matrix. It also contains purified components of human and animal origin, purified chemicals, preservatives and stabilizers.
No reconstitution is required.
Before each use, the vial should be thoroughly mixed by gentle inversion for approximately three minutes to obtain a homogeneous solution. The control should then be brought to room temperature.
For the respective analytical procedure, the control is handled in the same way as a patient sample.
Independent Quality Control for Urinalysis Systems
Duotrol® U Dipstick is manufactured independently of the manufacturers of the reagent strips and analytical instruments with which it is used. The control material has not been developed exclusively for a particular instrument, reagent strip or method from a single manufacturer.
This provides laboratories with an independent means of monitoring analytical performance across different urinalysis systems.
With Level 2, particular emphasis is placed on monitoring positive reactions and elevated measurement ranges. Results outside the expected range may indicate that the reagent strips, reagent lot, instrument reading or other elements of the analytical procedure should be reviewed.
Quality Control for Diagnostic Testing in vitro
Duotrol® U Dipstick Level 2 is intended for quality control of diagnostic testing in vitro. The liquid urine control is analyzed alongside human urine samples according to the laboratory's established quality control procedures.
Results are compared with the target values or expected ranges assigned to the respective analytical method.
This allows Level 2 to support continuous monitoring of analytical performance where positive reactions and elevated results are expected.
Why Use Level 1 and Level 2 Together?
The two Duotrol® U Dipstick control levels address different parts of the analytical response range.
Duotrol® U Dipstick Level 1 focuses on the lower control range and provides negative or low-level results for many common urine reagent strip parameters.
Level 2 has a different purpose. It provides positive reactions and elevated ranges for numerous urine parameters.
Nitrite illustrates this distinction particularly clearly: a negative result is expected with Level 1, whereas Level 2 provides a positive nitrite result. Similar differences are found across a number of other reagent strip parameters.
Using both levels allows laboratories to assess whether an analytical system can reliably distinguish and evaluate different response ranges.
Storage and Stability After Opening
Unopened Duotrol® U Dipstick Level 2 should be stored in its original packaging, protected from light, at +2 °C to +8 °C. Under these conditions, the control remains stable until the stated expiry date.
Do not freeze.
After opening and when protected from light, the parameters remain stable:
- for 6 weeks at +18 °C to +25 °C
- for 3 months at +2 °C to +8 °C
The vial should be closed immediately after use. Prolonged exposure to air should be avoided, as evaporation can particularly affect electrolyte results and may lead to falsely elevated concentrations in the control urine.
Product Characteristics
Product: Duotrol® U Dipstick Level 2
Application: Quality control for urinalysis
Control level: Higher control range
Primary focus: Positive reactions and elevated urine parameters
Control material: Liquid control based on human urine
Testing: Qualitative and semi-quantitative urine analysis
Applications: Biochemical, chemical and microscopic urinalysis
Evaluation: Visual or with suitable analytical systems
Reconstitution: Not required
Contents: 1 × 15 mL
Storage before opening: +2 °C to +8 °C, protected from light
Duotrol® U Dipstick Level 2 for Elevated Urine Parameters
Duotrol® U Dipstick Level 2 provides targeted quality control for positive reactions and elevated results in professional urinalysis. It enables laboratories to verify whether urine reagent strips and suitable analytical systems reliably detect analytes when present and correctly reproduce the corresponding response ranges.
The ready-to-use liquid urine matrix can be incorporated into a variety of urinalysis procedures and, depending on the method, supports both visual and automated evaluation.
Duotrol® U Dipstick Level 1 complements this approach by covering the lower control range. Together, the two levels enable differentiated monitoring across negative, low and elevated analytical responses.
Additional independent control materials for other areas of laboratory diagnostics are available in our Quality Controls category.
Frequently Asked Questions About Duotrol® U Dipstick Level 2
What Is Duotrol® U Dipstick Level 2 Used For?
Duotrol® U Dipstick Level 2 is a liquid quality control for monitoring positive reactions and elevated results in qualitative and semi-quantitative urinalysis.
Which Parameters Can Be Monitored with Level 2?
Depending on the reagent strip or analytical system, parameters including protein, glucose, ketones, bilirubin, blood, nitrite, urobilinogen, leukocytes, specific gravity, creatinine and albumin or microalbumin can be monitored.
Is Nitrite Positive in Duotrol® U Dipstick Level 2?
Yes. A positive nitrite result is expected for Level 2 with the listed reagent strip systems, allowing the positive nitrite reaction of the respective system to be monitored.
Can Level 2 Be Used for hCG Quality Control?
For several listed hCG test systems, Level 2 provides a positive control result. Suitability for a specific method depends on the available target values or expected ranges for that procedure.
Is Duotrol® U Dipstick Level 2 Ready to Use?
Yes. The control is supplied as a liquid material and does not require reconstitution. Before use, the vial should be gently inverted for approximately three minutes and brought to room temperature.
What Is the Difference Between Level 1 and Level 2?
Level 2 focuses on positive reactions and elevated measurement ranges. Level 1 primarily covers negative and low-level results for many common urine parameters. The two controls therefore address different analytical response ranges.
How Long Is Level 2 Stable After Opening?
When protected from light, the parameters remain stable for 3 months at +2 °C to +8 °C or for 6 weeks at +18 °C to +25 °C.
| Parameter | Albumin, Bilirubin, Blood (hemoglobin), Creatinine, Protein, Protein / Crea ratio, Glucose, hCG, Ketones, Leukocytes, Microalbumin, Sodium, Osmolality, pH, spec. weight, Urobilinogen |
|---|---|
| Packaging unit | 1 x 15 mL |
If required, we can provide you with device-specific target values using statistical analysis. Information on participating in target value determination can be found here.
A product-specific IFU, including current target values, safety data sheets (MSDS), data sheets instead of MSDS, and CoAs are available as PDF downloads directly from our database: https://dokumente.biomed.de/
You will find your login details on your delivery note.