Duotrol® Urine Liquid Level 1 – Urine Quality Control
Liquid urine quality control at a low control level for clinical chemistry testing.
Duotrol® Urine Liquid Level 1 – Liquid Urine Quality Control
Duotrol® Urine Liquid Level 1 is a liquid quality control material for monitoring clinical chemistry urine testing at a low control level. It supports medical laboratories in routinely assessing the precision and accuracy of analytical procedures and monitoring the reliability of measurement results.
Level 1 represents the lower of the two clinically relevant control levels available for Duotrol® Urine Liquid. Duotrol® Urine Liquid Level 2 is available as a complementary quality control material for the high control level.
The liquid urine matrix is processed in the clinical chemistry analyzer in the same way as a patient sample. Device- or method-specific target values and target ranges are available for numerous parameters, making Duotrol® Urine Liquid Level 1 suitable for routine internal quality control of a broad range of clinical chemistry urine measurements.
Why Is Quality Control at a Low Control Level Important?
Internal quality control is used to continuously monitor the analytical performance of a testing procedure. It is not sufficient to determine whether an analytical system generally produces plausible results. Precision and accuracy should also be assessed at different concentration levels.
Duotrol® Urine Liquid Level 1 provides a low, clinically relevant control level for this purpose. Regular control measurements can help laboratories identify changes in analytical performance and monitor testing procedures under established laboratory conditions.
Quality control results are not interpreted as patient results. They are used to assess analytical performance and to verify whether measured control values remain within the ranges established for the respective procedure.
Which Parameters Can Be Monitored with Duotrol® Urine Liquid Level 1?
Duotrol® Urine Liquid Level 1 is designed as a multiparameter quality control material for various clinical chemistry urine measurements.
Depending on the analyzer and method used, target values or target ranges are available for parameters including:
- Amylase
- Calcium
- Chloride
- Cortisol
- Creatinine
- Total protein
- Glucose
- Uric acid
- Urea or urea nitrogen
- Potassium
- Magnesium
- Microalbumin
- Sodium
- Phosphorus
Method-specific values are also available for additional measurements and physical properties, including osmolality, pH and specific gravity.
For hCG testing, Level 1 represents the negative control level.
The parameters that can be monitored with a particular analyzer depend on the target values available for the respective device and method combination.
Device- and Method-Specific Target Values
Target values for Duotrol® Urine Liquid are determined on a lot-specific basis using representative measurements. Depending on the analyte, the specified values may be device- or method-specific.
For Level 1, target values are available for various analytical systems from manufacturers including Abbott, Beckman Coulter, DiaSorin, Roche and Siemens. This allows the control material to be used in different clinical chemistry laboratory environments.
The specified target ranges are based on the maximum permissible deviation from the assigned value according to the German Medical Association guidelines on quality assurance in medical laboratory examinations (Rili-BÄK).
In accordance with good laboratory practice, laboratories should also establish their own control ranges taking into account the methods used and their individual laboratory conditions.
Independent Quality Control for Clinical Chemistry Analyzers
Duotrol® Urine Liquid is an independently manufactured quality control material. It has not been developed exclusively for instruments, test kits or methods from a particular manufacturer.
Independent quality control provides laboratories with the opportunity to assess analytical performance without relying exclusively on control material associated with a specific analyzer or reagent manufacturer.
This is particularly relevant for laboratories that systematically monitor their analytical processes and integrate different analyzers or methods into their quality management procedures.
Liquid Urine Matrix for Routine Quality Control
Duotrol® Urine Liquid Level 1 is supplied as a liquid control material based on a human urine matrix. The matrix contains defined components for monitoring various clinical chemistry urine parameters.
Before each use, the control is mixed by gentle inversion to obtain a homogeneous solution and is then processed in the respective analyzer in the same way as a patient sample.
The liquid format facilitates integration into routine laboratory workflows because the control material does not require reconstitution before use.
How Is Duotrol® Urine Liquid Level 1 Used?
Duotrol® Urine Liquid Level 1 is generally processed in the clinical chemistry analyzer in the same way as a patient sample. The specific procedure depends on the analytical system and method used.
Before measurement, the control vial is gently inverted to obtain a homogeneous solution. The vial should be closed again immediately after removing the required amount of control material.
Appropriate reagents for the respective parameter and, where required, a suitable calibrator are needed for analysis.
The measured control values are subsequently compared with the control ranges established for the respective lot, method or analyzer combination.
Combining Level 1 and Level 2 for Quality Control
Monitoring an analytical procedure at different control levels enables laboratories to assess analytical performance across different concentration ranges.
Duotrol® Urine Liquid is therefore available in two clinically relevant control levels.
Duotrol® Urine Liquid Level 1 covers the low control level.
Duotrol® Urine Liquid Level 2 complements quality control at the high control level.
Using both levels allows analytical performance to be monitored across different concentration ranges.
Storage and Stability
Duotrol® Urine Liquid Level 1 should be stored at +2 °C to +8 °C and must not be frozen.
When unopened, stored in its original packaging and kept under the specified conditions, the quality control material remains stable until the stated expiry date. After opening, the parameters generally remain stable until the expiry date when the vial is stored at +2 °C to +8 °C.
Creatinine values may decrease during storage. Visible turbidity can indicate microbial growth, in which case the affected vial must not be used.
Product Characteristics of Duotrol® Urine Liquid Level 1
Product: Duotrol® Urine Liquid Level 1
Application: Quality control for clinical chemistry urine measurements
Control level: Low
Matrix: Human urine matrix
Format: Liquid
Pack size: 1 × 15 mL
Article number: 107451
Storage: +2 °C to +8 °C
Application: Clinical chemistry analyzers
Duotrol® Urine Liquid Level 1 for Internal Quality Control
Duotrol® Urine Liquid Level 1 provides laboratories with a liquid control material for the routine monitoring of clinical chemistry urine measurements at a low control level.
The combination of a human urine matrix, a broad range of parameters and device- or method-specific target values enables the control material to be integrated into different laboratory workflows.
For quality control at the higher control level, Duotrol® Urine Liquid Level 1 can be complemented by Duotrol® Urine Liquid Level 2.
Further control materials for different areas of laboratory diagnostics are available in our Quality Controls category.
Frequently Asked Questions About Duotrol® Urine Liquid Level 1
What Is Duotrol® Urine Liquid Level 1?
Duotrol® Urine Liquid Level 1 is a liquid quality control material based on a human urine matrix. It is used to quantitatively monitor the precision and accuracy of clinical chemistry urine measurements at a low control level.
What Is the Difference Between Duotrol® Urine Liquid Level 1 and Level 2?
The two products represent different control levels. Level 1 covers the low control level, while Level 2 is intended for quality control at the high control level. The two levels can be used together to monitor analytical performance across different concentration ranges.
Which Parameters Can Be Monitored with Level 1?
Depending on the analyzer and method used, target values are available for numerous parameters, including creatinine, microalbumin, glucose, calcium, sodium, potassium, chloride, phosphorus, magnesium, uric acid, urea, amylase, total protein and cortisol.
Is Duotrol® Urine Liquid Level 1 Ready to Use?
The control material is supplied in liquid form and does not require reconstitution. Before use, the vial is gently inverted to obtain a homogeneous solution.
Is Duotrol® Urine Liquid Level 1 Limited to a Specific Analyzer Manufacturer?
No. The control material is independently manufactured and was not developed exclusively for instruments, test kits or methods from a single manufacturer. Suitable target values or laboratory-established control ranges must be available for the method used.
How Should Duotrol® Urine Liquid Level 1 Be Stored?
The control material should be stored at +2 °C to +8 °C and must not be frozen.
What Is the Pack Size of Duotrol® Urine Liquid Level 1?
Duotrol® Urine Liquid Level 1 is supplied as 1 × 15 mL. The article number is 107451.
| Parameter | Amylase, Calcium, Chlorid, Cortisol, Creatinine, Total Protein, Glucose, Uric Acid, Urea, Urea nitrogen, hCG, Potassium, Magnesium, Microalbumin, Sodium, pH, Phosphorus, spec. weight |
|---|---|
| Packaging unit | 1 x 15 mL |
If required, we can provide you with device-specific target values using statistical analysis. Information on participating in target value determination can be found here.
A product-specific IFU, including current target values, safety data sheets (MSDS), data sheets instead of MSDS, and CoAs are available as PDF downloads directly from our database: https://dokumente.biomed.de/
You will find your login details on your delivery note.