T4 Rapid Test – Quantitative Measurement

EAN: 06974464591456
Article number
5294C4X025
Packaging unit
25 test cassettes, 25 pipette tips, 1 ID chip, sample dilution buffer

Quantitative T4 rapid test for measurement of thyroxine in serum, plasma and whole blood using the BIOspeed analyzer.

€205.00
Excl. 19% VAT , excl. Shipping Cost

T4 Rapid Test Kit for Quantitative Measurement of Thyroxine

The T4 Rapid Test Kit enables quantitative measurement of tetraiodothyronine (thyroxine, T4) in human serum, plasma and whole blood. T4 is one of the principal thyroid hormones and an important laboratory parameter for the assessment of thyroid function.

Quantitative measurement is performed using the BIOspeed analyzer. After an incubation time of 15 minutes, the T4 concentration is determined based on the fluorescence signal.

What Is T4?

T4, also known as thyroxine or tetraiodothyronine, is one of the principal thyroid hormones, together with triiodothyronine (T3). It is produced by the thyroid gland and released into the bloodstream.

T4 serves, among other functions, as a precursor for the formation of the biologically more active T3. The conversion of T4 to T3 takes place predominantly outside the thyroid gland in peripheral tissues.

Most circulating T4 is bound to transport proteins. Only a small proportion circulates as free thyroxine (fT4). Total T4 measurement determines both the protein-bound and free fractions of the hormone.

What Is the Role of T4 in Thyroid Diagnostics?

T4 concentration provides important information about thyroid hormone status and can be evaluated together with TSH, T3 and the free thyroid hormones to assess thyroid function.

T4 should not be interpreted in isolation. For a differentiated diagnostic assessment, TSH, T3, fT3 and fT4, as well as clinical findings and other laboratory results, are taken into consideration.

Evaluating several thyroid parameters together provides a more comprehensive picture of the hypothalamic-pituitary-thyroid axis.

What Is the Role of T4 in Hypothyroidism and Hyperthyroidism?

Changes in T4 concentration can occur in thyroid dysfunction.

In primary hypothyroidism, thyroid hormone production is reduced. T4 concentrations may be decreased, while TSH typically increases as a consequence of reduced negative feedback.

In primary hyperthyroidism, the thyroid gland produces increased amounts of thyroid hormones. T4 concentrations may be elevated, while TSH secretion is typically suppressed.

The actual laboratory pattern depends on the underlying disorder. T4 results are therefore evaluated together with TSH, other thyroid parameters and the clinical presentation.

T4 and T3 – How Are These Thyroid Hormones Related?

T4 and T3 are closely linked physiologically. The thyroid gland predominantly releases T4, which is partially converted to T3 in peripheral tissues.

T3 has greater biological activity and mediates a substantial proportion of thyroid hormone effects. T4 therefore acts not only as a thyroid hormone itself but also as an important precursor for the production of T3.

Evaluating both hormones can provide additional information about thyroid hormone status.

Total T4 and Free T4 – What Is the Difference?

Most T4 circulating in the blood is bound to transport proteins. Only a small proportion is present as free T4 (fT4).

Total T4 represents the overall T4 concentration, including both protein-bound and free hormone. In contrast, fT4 measurement specifically determines the free hormone fraction.

This distinction is relevant when interpreting laboratory results. Changes in the concentration or binding properties of transport proteins can influence total T4 levels without a corresponding change in the free T4 concentration.

Why Are T4 and TSH Evaluated Together?

TSH and T4 reflect different levels of thyroid regulation. TSH is produced by the pituitary gland and regulates thyroid activity, while T4 is produced directly by the thyroid gland.

Through negative feedback, thyroid hormones in turn influence TSH secretion. Evaluating both parameters together therefore provides important information about the function of the hypothalamic-pituitary-thyroid axis.

Different patterns can occur in primary or central thyroid dysfunction. T4 and TSH are therefore interpreted together with other thyroid parameters and clinical findings.

Benefits of the T4 Rapid Test Kit

  • Quantitative measurement of thyroxine (T4)
  • Suitable for serum, plasma and whole blood
  • Results after 15 minutes
  • Timely quantitative measurement at the point of care
  • Evaluation using the BIOspeed analyzer
  • Compatible with BIOspeed Single and BIOspeed Multi
  • Can be complemented by additional thyroid parameters

Quantitative T4 Measurement Using Fluorescence Immunoassay

The T4 Rapid Test Kit uses a fluorescence immunochromatographic assay. T4 present in the sample binds to fluorescence-labelled anti-T4 antibodies. Antibodies that remain unbound to T4 can subsequently bind to immobilised T4 antigens on the test membrane.

This results in an inverse relationship between the T4 concentration and the fluorescence intensity of the test line: the more T4 is present in the sample, the fewer unbound fluorescence-labelled antibodies are available to bind at the test line.

The BIOspeed analyzer measures the fluorescence signal and quantitatively determines the T4 concentration using lot-specific calibration data. The corresponding calibration curve is stored on the ID chip.

Performance Characteristics of the T4 Rapid Test Kit

Parameter: T4 (tetraiodothyronine/thyroxine)

Determination: Quantitative

Sample material: Serum, plasma or whole blood

Sample volume: 75 µL serum or plasma / 150 µL whole blood

Sample application: 75 µL of the prepared sample

Test principle: Fluorescence immunochromatographic assay

Evaluation: BIOspeed Single or BIOspeed Multi

Incubation time: 15 minutes

Kit contents: 25 test cassettes, sample dilution buffer, 25 pipette tips and 1 ID chip

T4 and Other Thyroid Parameters with BIOspeed

In addition to T4, further quantitative thyroid tests are available for the BIOspeed analyzer system, including TSH, T3, fT3 and fT4.

The individual parameters reflect different aspects of thyroid function. TSH primarily provides information about pituitary regulation of the thyroid gland. T3 and T4 represent the total concentrations of the respective thyroid hormones, whereas fT3 and fT4 determine their free hormone fractions.

Depending on the clinical question, these parameters can be measured individually or in combination to support the assessment of thyroid function.

T4 Rapid Test for Point-of-Care Thyroid Diagnostics

The T4 Rapid Test Kit enables quantitative measurement of thyroxine with an incubation time of 15 minutes. Serum, plasma and whole blood can be used as sample materials.

The test is suitable for healthcare facilities requiring timely quantitative T4 measurement and interpretation of the result together with other thyroid parameters and clinical findings.

Further quantitative rapid tests and compatible analyzers are available in our BIOspeed Analyzers and Rapid Test Kits category.

More Information
Parameter T4
Packaging unit 25 test cassettes, 25 pipette tips, 1 ID chip, sample dilution buffer
are usually dispatched on the same day (no dispatch on Fridays)
Orders placed before 12 noon
are usually dispatched on the same day (no dispatch on Fridays)
in an environmentally friendly box
Refrigerated shipping
in an environmentally friendly box
from 2.000 € Germany-wide
Free shipping
from 2.000 € Germany-wide