Only medical facilities

SAA Rapid Test – Quantitative Serum Amyloid A

EAN: 06974464591517
Article number
5064C4X025
Packaging unit
25 test cassettes, 25 pipette tips, 1 ID chip, sample dilution buffer

Quantitative SAA rapid test for measurement of Serum Amyloid A in serum, plasma, whole blood and capillary blood using BIOspeed Single or BIOspeed Multi. 3-minute incubation time.

€184.50
Excl. 19% VAT , excl. Shipping Cost

SAA Rapid Test Kit for Quantitative Measurement of Serum Amyloid A

The SAA Rapid Test Kit enables the quantitative measurement of Serum Amyloid A (SAA) in human serum, plasma and whole blood. Serum Amyloid A is an acute-phase protein whose concentration can increase markedly during inflammatory responses. Quantitative SAA measurement supports the diagnostic assessment of inflammatory and infectious diseases.

SAA responds dynamically to inflammatory processes and can therefore provide additional information about inflammatory activity. In addition to assessing acute changes, monitoring SAA concentrations over time can provide useful information about the course of an inflammatory response.

Quantitative analysis is performed using BIOspeed Single or BIOspeed Multi. Following sample application, the test cassette is incubated for 3 minutes and then immediately analyzed quantitatively.

What Is Serum Amyloid A (SAA)?

Serum Amyloid A, or SAA, is an acute-phase protein and part of the innate immune response. It is produced predominantly in the liver, with synthesis increasing in response to pro-inflammatory signaling during inflammatory processes.

During a pronounced acute-phase response, SAA concentrations in the blood can increase markedly. SAA responds dynamically to changes in inflammatory activity.

Quantitative measurement of Serum Amyloid A provides a laboratory parameter for assessing this response. Because elevated SAA concentrations can occur in a variety of conditions, results should always be interpreted together with the clinical presentation and other laboratory findings.

When Is SAA Measurement Useful?

Measurement of Serum Amyloid A can provide additional diagnostic information when an inflammatory or infectious disease is suspected or when the course of an inflammatory process is being assessed.

SAA measurement may be useful for:

  • Assessment of an acute inflammatory response
  • Supporting the evaluation of infectious diseases
  • Assessment of inflammatory activity
  • Monitoring the course of inflammatory processes
  • Complementary assessment together with other inflammatory markers

SAA is not a disease-specific biomarker. An elevated concentration indicates an acute-phase response but cannot, on its own, establish a diagnosis of a specific disease.

What Is the Role of SAA in Infections?

Infections activate the innate immune system and can trigger a pronounced acute-phase response. Serum Amyloid A is one of the proteins whose concentration can increase as part of this response.

Quantitative SAA measurement can therefore support the assessment of infectious diseases. Elevated concentrations may occur in both bacterial and viral infections.

An SAA result alone does not reliably distinguish between bacterial and viral infection. Clinical symptoms, the course of the illness and additional laboratory findings remain essential for diagnostic interpretation.

What Is the Role of SAA in Inflammatory Diseases?

Infections are not the only conditions associated with elevated SAA concentrations. Non-infectious inflammatory processes can also induce an acute-phase response accompanied by an increase in Serum Amyloid A.

Quantitative SAA measurement can therefore provide additional information about the activity of an inflammatory process.

Changes in SAA concentration over time can be particularly informative. Rising or falling SAA concentrations are interpreted together with the clinical course and other laboratory parameters.

Why Can Serial SAA Measurements Be Useful?

Inflammatory responses change over the course of a disease. A single laboratory result therefore represents only the situation at the time the sample was collected.

Repeated quantitative SAA measurements can be used to monitor changes in SAA concentration. Depending on the disease and clinical question, this can provide additional information about the dynamics of the inflammatory response.

Serial measurements should not be interpreted in isolation. SAA results should be considered together with the patient's clinical course and other diagnostic findings.

Quantitative SAA Measurement from Capillary Blood

Capillary blood can also be used for near-patient testing. The capillary blood sample is collected from a fingertip and processed immediately for testing.

This allows quantitative SAA measurement to be integrated into diagnostic workflows in which venous blood collection is not required or where near-patient testing is preferred.

How Should SAA Results Be Interpreted?

An elevated SAA concentration indicates activation of the acute-phase response but is not specific to a single disease.

Both infectious and non-infectious inflammatory processes can lead to elevated SAA concentrations. The result should therefore not be used in isolation to establish a diagnosis.

Clinical interpretation should take into account the patient's condition, additional laboratory parameters and, where appropriate, further diagnostic investigations.

Benefits of the SAA Rapid Test Kit

  • Quantitative measurement of Serum Amyloid A (SAA)
  • Supports the assessment of inflammatory and infectious diseases
  • Suitable for monitoring the dynamics of inflammatory processes
  • Serum, plasma, whole blood and capillary blood can be used
  • Quantitative immunofluorescence analysis
  • 3-minute incubation time
  • Analysis using BIOspeed Single or BIOspeed Multi
  • Can be combined with additional inflammatory and infection biomarkers

How Does the Quantitative SAA Rapid Test Work?

The SAA Rapid Test Kit is based on a fluorescence immunochromatographic assay using a double-antibody sandwich method.

Serum Amyloid A in the sample binds to fluorescence-labelled anti-SAA antibodies. The resulting immune complexes migrate along the nitrocellulose membrane and bind to a second anti-SAA antibody immobilized on the test strip.

As the SAA concentration increases, the intensity of the fluorescence signal increases. The BIOspeed analyzer measures this signal and quantitatively determines the SAA concentration.

The lot-specific calibration curve is stored on the ID chip and is used to calculate the quantitative SAA concentration.

Performance Characteristics of the SAA Rapid Test Kit

Parameter: Serum Amyloid A (SAA)

Measurement: Quantitative

Sample material: Serum, plasma, whole blood or capillary blood

Sample volume: 5 µL

Sample application: 75 µL of the prepared sample

Test principle: Fluorescence immunochromatographic assay

Analysis: BIOspeed Single or BIOspeed Multi

Incubation time: 3 minutes

Kit contents: 25 test cassettes, sample dilution buffer, 25 pipette tips and 1 ID chip

For sample preparation, 5 µL of the patient sample is used. Subsequently, 75 µL of the prepared sample is applied to the test cassette. After 3 minutes of external incubation, the test cassette is immediately analyzed using the BIOspeed analyzer.

Quantitative SAA Measurement with BIOspeed Single or BIOspeed Multi

The SAA Rapid Test Kit can be quantitatively analyzed using BIOspeed Single or BIOspeed Multi.

BIOspeed Single is designed for quantitative single-test measurements according to diagnostic demand. BIOspeed Multi features six test channels and enables several tests to be processed in parallel. The appropriate analyzer can therefore be selected according to the required testing workflow and sample throughput.

SAA and Other Inflammatory Markers

In the assessment of inflammatory and infectious diseases, SAA can be considered together with other laboratory parameters. Different biomarkers reflect different aspects of the immune and inflammatory response and can provide complementary information depending on the clinical question.

In addition to SAA, the BIOspeed analyzer system offers quantitative rapid tests for CRP and hsCRP, Procalcitonin (PCT), Interleukin-6 (IL-6) and Ferritin.

CRP is a widely used acute-phase protein for the assessment and monitoring of inflammatory processes.

PCT is particularly relevant in the assessment of systemic bacterial infections and suspected sepsis.

IL-6 is a pro-inflammatory cytokine involved in the early stages of the immune response.

Ferritin is primarily used to assess iron metabolism and iron stores. At the same time, ferritin is an acute-phase protein and may be elevated during inflammatory processes.

The selection of individual biomarkers or combinations of biomarkers depends on the clinical question.

Quantitative SAA Measurement with BIOspeed

The SAA Rapid Test Kit enables quantitative measurement of Serum Amyloid A in serum, plasma, whole blood and capillary blood. As a dynamic acute-phase protein, SAA can provide additional information in the assessment of inflammatory and infectious diseases.

Following sample application, the test cassette is incubated for 3 minutes and then immediately analyzed quantitatively using BIOspeed Single or BIOspeed Multi.

Further quantitative rapid tests and the corresponding analyzers are available in the Point-of-Care Analyzers & Accessories category.

Frequently Asked Questions About SAA and the SAA Rapid Test

What Is SAA?

SAA stands for Serum Amyloid A. It is an acute-phase protein whose concentration in the blood can increase markedly during inflammatory processes.

What Does an Elevated SAA Level Indicate?

An elevated SAA level indicates activation of the acute-phase response. Increased concentrations can occur in both infectious and non-infectious inflammatory processes. An SAA result alone therefore cannot establish a diagnosis of a specific disease.

When Is SAA Measurement Useful?

Quantitative SAA measurement can support the assessment of inflammatory and infectious diseases. Changes in SAA concentration over time can also provide additional information about inflammatory activity.

Is SAA an Inflammatory Marker?

Yes. Serum Amyloid A is an acute-phase protein used as an inflammatory marker. Its concentration can increase markedly during activation of the acute-phase response.

Can SAA Be Elevated in Both Bacterial and Viral Infections?

Yes. SAA concentrations can be elevated in both bacterial and viral infections. An elevated SAA result alone therefore does not reliably distinguish between bacterial and viral infection.

Can SAA Be Measured from Capillary Blood?

Yes. In addition to serum, plasma and venous whole blood, capillary blood can be used for SAA measurement. The capillary blood sample is collected from a fingertip and processed immediately.

How Long Does the SAA Rapid Test Take?

The incubation time is 3 minutes. When external incubation is used, the test cassette is subsequently inserted immediately into the BIOspeed analyzer for quantitative analysis.

Which BIOspeed Analyzers Can Be Used for SAA Measurement?

The SAA Rapid Test Kit can be quantitatively analyzed using BIOspeed Single or BIOspeed Multi. BIOspeed Single is designed for individual measurements, while BIOspeed Multi provides six test channels for processing several tests in parallel.

More Information
Parameter SAA (Serum Amyloid A)
Packaging unit 25 test cassettes, 25 pipette tips, 1 ID chip, sample dilution buffer
are usually dispatched on the same day (no dispatch on Fridays)
Orders placed before 12 noon
are usually dispatched on the same day (no dispatch on Fridays)
in an environmentally friendly box
Refrigerated shipping
in an environmentally friendly box
from 2.000 € Germany-wide
Free shipping
from 2.000 € Germany-wide